Products
EBS1C-F series AC Contactor is applicable to the circuits up to the rated voltage 1000V AC 50Hz or 60Hz, rated current up to 780A, for long distance breaking circuit and frequently starting or controlling the motor.
Contactor?Model | Appointed
thermal current (A) |
Rated operation?current?(A) | The max.power or controllable???3-phase squirrel-cage motor(kw) | Weight
(kg) |
Mechanical?life | Electric?life | Mechanical?life | ||||||||
Operation | Time
×104 |
Operation | Time
×104 |
Model | Rated??current | ||||||||||
380V | 660V | 1000V | 220V | 380V | 660V | 1000V | |||||||||
EBS1C-F115 |
200 |
115 |
65 |
40 |
kW | kW | kW | kW |
3.6 |
1200 |
300 |
1200 |
120 |
RT16-2 |
250 |
30 | 55 | 80 | 65 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
40 | 75 | 110 | 85 | ||||||||||||
EBS1C-F150 |
220 |
150 |
80 |
50 |
kW | kW | kW | kW |
3.7 |
1200 |
300 |
1200 |
120 |
RT16-2 |
355 |
40 | 75 | 100 | 65 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
53 | 100 | 136 | 85 | ||||||||||||
EBS1C-F185 |
275 |
185 |
95 |
65 |
kW | kW | kW | kW |
4.6 |
600 |
300 |
1200 |
60 |
RT16-3 |
425 |
55 | 90 | 110 | 100 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
75 | 125 | 150 | 135 | ||||||||||||
EBS1C-F225 |
315 |
225 |
115 |
80 |
kW | kW | kW | kW |
4.7 |
600 |
300 |
600 |
60 |
RT16-3 |
500 |
68 | 110 | 120 | 100 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
90 | 150 | 175 | 136 | ||||||||||||
EBS1C-F265 | 350 | 265 | 150 | 95 | kW | kW | kW | kW |
7.1 |
600 |
100 |
300 |
60 |
RT16-3 |
630 |
75 | 132 | 160 | 147 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
100 | 180 | 220 | 200 | ||||||||||||
EBS1C-F330 |
400 |
330 |
185 |
115 |
kW | kW | kW | kW | 8.5 | 600 | 100 | 300 | 60 | RT16-4 | 800 |
100 | 165 | 220 | 160 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
135 | 221 | 300 | 220 | ||||||||||||
EBS1C-F400 |
500 |
400 |
225 |
150 |
kW | kW | kW | kW |
8.5 |
600 |
100 |
300 |
60 |
RT16-4 |
800 |
115 | 200 | 280 | 185 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
155 | 270 | 380 | 250 | ||||||||||||
EBS1C-F500 |
700 |
500 |
265 |
185 |
kW | kW | kW | kW |
10.8 |
600 |
100 |
300 |
60 |
RT16-4 |
1000 |
147 | 250 | 335 | 335 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
200 | 340 | 450 | 450 | ||||||||||||
EBS1C-F630 |
1000 |
630 |
330 |
225 |
kW | kW | kW | kW |
17.4 |
600 |
100 |
300 |
60 |
RT16 |
1250 |
200 | 335 | 450 | 425 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
270 | 450 | 610 | 570 | ||||||||||||
EBS1C-F780 |
1500 |
780 |
450 |
300 |
kW | kW | kW | kW |
40 |
600 |
100 |
300 |
60 |
RT16 |
1600 |
220 | 400 | 475 | 450 | ||||||||||||
HP.Ch | HP.Ch | HP.Ch | HP.Ch | ||||||||||||
300 | 540 | 635 | 605 |
Rated operating
current 380V?AC-3 A |
Conventional thermal current
A |
Standard?power ratings?for 3?phase?motors?50-60Hz?AC-3 | Poles | Type?Code | ||
220V
230V |
380V
400V |
415V
440V |
230V?50Hz
Please contact us?for other coil?voltage. |
|||
KW | KW | KW | ||||
115 | 200 | 30 | 55 | 60 | 3
4 |
1C-F 115/3P5
1C-F 115/4P5 |
150 | 220 | 40 | 75 | 80 | 3
4 |
1C-F 150/3P5
1C-F 150/4P5 |
185 | 275 | 55 | 90 | 100 | 3
4 |
1C-F 185/3P5
1C-F 185/4P5 |
225 | 315 | 63 | 110 | 120 | 3
4 |
1C-F?225/3P5
1C-F?225/4P5 |
265 | 350 | 75 | 132 | 140 | 3
4 |
1C-F?265/3P5
1C-F?265/4P5 |
330 | 400 | 100 | 165 | 180 | 3
4 |
1C-F?330/3P5
1C-F?330/4P5 |
400 | 500 | 115 | 200 | 220 | 3
4 |
1C-F?400/3P5
1C-F?400/4P5 |
500 | 700 | 147 | 250 | 280 | 3
4 |
1C-F?500/3P5
1C-F?500/4P5 |
630 | 1000 | 200 | 335 | 375 | 3
4 |
1C-F?630/3P5
1C-F?630/4P5 |
780 | 1500 | 220 | 400 | 425 | 3
4 |
1C-F?780/3P5
1C-F?780/4P5 |